Latest Hand Leg Neck Knee Pain Relief Laser Physical Therapy with Two Probes for Good Massage

Model NO.
two probe laser
Certification
CE
Medical Device Regulatory Type
Type 1
Item
Laser Physiotherapy Machine
Laser Medium
Gaalas-Semiconductor
Terminal Laser Output Power
500MW
Ambient Temperature
5 Oc-40 Oc
Electrical Power Supply
110V - 220V, 50/60Hz
Relative Humidity
80%
Probe Indication Light Wavelength
650nm (6PCS)
Predominantly Laser Output
810nm (1PCS)
Ce
Medical Ce
Warranty
One Year
Trademark
OEM
Transport Package
Packed with Colorful Carton
Specification
52*52*23cm, 8kg
Origin
China
HS Code
901910100
We consistently execute our spirit of ''Innovation bringing progress, Highly-quality ensuring subsistence, Administration advertising and marketing gain, Credit history attracting buyers for Latest Hand Leg Neck Knee Pain Relief Laser Physical Therapy with Two Probes for Good Massage, The product will supply to all over the world, such as: Chicago, Iraq, India, Welcome to visit our company, factory and our showroom where displays various products that will meet your expectation. Meanwhile, it is convenient to visit our website, and our sales staff will try their best to provide you the best service. Please contact us if you need more information. Our aim is to help customers realize their goals. We are making great efforts to achieve this win-win situation.
GUANGZHOU SAN HONG TECH CO., LTD. Diamond / Audited Supplier
   Latest Hand leg neck knee pain relief laser physical therapy with two probes for good massage 
Indications of Use: The energy emitted provides temporary increase in microcirculation, temporary relief of local muscle and joint aches, pains and stiffness, relaxation of muscles; For muscle spasms, minor pain and stiffness associated with arthritis.  

I Laser medium: GaAIAs – Semiconductor,
 
  1. Power supply:AC230V, 50/60Hz
  2. Consumption: 20 VA
  3. Terminal laser output: Maximum terminal output for each probe of laser emitter: 500mW±20%, spot diameter of laser beam<l Omm.
  4. Wavelength of probe central laser output: 81 Onm±30nm.
  5. Power supply:AC230V, 50/60Hz
  6. Consumption: 20 VA
  7. Terminal laser output: Maximum terminal output for each probe of laser emitter: 500mW±20%, spot diameter of laser beam<l Omm.
  8. Wavelength of probe central laser output: 81 Onm±30nm.
  9. Beam divergence angle: cÞx=0.26 rad, O.=0.78 rad.
  10. Laser output power instability St: < 1 0%.
  11. Il. Probe peripheral laser wavelength: 650nm±30nm
  12. Time scope and precision: Time range is from Oto 30 minutes, adjustable by 30 seconds, time error should be less than ± 3%.