Explosion Proof Smart High Accuracy 4~20 mA & Hart Absolute Pressure Transmitter

Model NO.
ASP2003B
Certification
ISO9001
Customized
OEM & ODM Are Accepted
Operating Temperature Range
-40ºC~85ºC
Range Down
100: 1
Insulation Resistance
>100mΩ (500VDC)
Trademark
Analog Systems
Transport Package
Cartons
Origin
China, Shanghai
HS Code
9026201090
Our primary intention should be to offer our clientele a serious and responsible enterprise relationship, delivering personalized attention to all of them for Explosion Proof Smart High Accuracy 4~20 mA & Hart Absolute Pressure Transmitter, The product will supply to all over the world, such as: Portugal, Greenland, Qatar, Thus far, our item associated with printer dtg a4 may be shown in most foreign nations as well as urban centers, which are sought after simply by targeted traffic. We all highly imagine that now we have the full capacity to present you with contented merchandise. Desire to collect requests of your stuff and produce the long-term co-operation partnership. We very seriously promise:Csame top quality, better price; exact same selling price, higher quality.
Analog Systems (SH) Co., Ltd. Diamond / Audited Supplier
I Product Introduction

The pressure transmitter is mainly applied to measure pressure, negative pressure, absolute pressure and other parameters of gas, liquid or vapor, then to converts these parameters into 4~20mA DC signal output. It can connect with HART manipulator to promote self-diagnosis, reset measuring range and auto-zero functions. One side of pressure transmitters δ cell receives measured absolute pressure signal, meanwhile, the other side is sealed to be base cell to measure absolute pressure of exhaust system, distillation tower, evaporator and crystallizer ect.

Application
Measuring absolute pressure of pipeline and storage tank in petroleum, petrochemical and chemical industry.
Meeting high stability and precision requirements in electric power, city gas and other utilities.
Realizing stable measurement under temperature & humidity strictly controlled conditions in iron, steel, nonferrous metal and ceramic fields.
Using in the fields of pulp and paper where the resistance of chemical liquid and corrosion liquid is required.
Realizing stable measurement under temperature & humidity strictly controlled condition in machinery and ship building fields.

II Performance Parameters

Zero shift volume
Maximum positive shift volume: difference between shift volume upper range and measuring range.
No negative shift volume.

Measuring range
Lower range limit: 0%URL~+100%URL-Span
Upper range limit: Span~+100%URL

Measuring range and zero adjustment
HART manipulator, local button, communication software supported by HART protocol.

Response time
When the electrical damping of the transmitter turns off, the response time of the step input applied to the transmitter from 10% to 90% of the output range is less or equal to 0.4s.
 

Measuring medium: liquid, gas and vapor
Operating Temperature Range:   -40ºC~85ºC
Accuracy: 0.1% F.S
Insulation resistance:  >100MΩ (100VDC)
Range down: 100:1
Damping value:   0.1~16s (Option)
Temperature affecting value: 0.1%F.S/10ºC
Output signal: 4~20mA(Max 22mA,Min 3.8mA)
Communication interface: HART
Intrinsic safety:  EX ia IIC T6
EMC:  EN 61326-1:2013
Enclosure rating:  IP68

 


 
III. Structural Drawing

 
V Selection Guide
 

Selection List  
Code 1
3
Product catagory
Absolute Pressure Transmitter
Code 2
C
D
Accuracy
0.25%
0.5%
Code 3
H
M
W
Output Signal
(4~20) mA & HART
(4~20) mA & ModBus
Wireless communication
Code 4
5
6
7
8
Measuring range
0-18.6 to 186 kPa
0-69 to 690 kPa
0-200 to 2000 kPa
0-690 to 6900 kPa
 Code 5
N
Q
S
M
G
F
R
C
 Process connection
NPT 1/4 Female
NPT 1/2 Female
NPT1/2 Male (NPT1/4 Female)
M20*1.5 Male
G1/2 Male
G1/4 Male
Remote
Customize
 Code 6
2
3
 Isolating diaphragm
316L stainless steel
Hastelloy C
 Code 7
N
F
P
 Material of Oring
Perbunan(NBR)
Viton(FKM)
Teflon(PTFE)
 Code 8
0
1
2
Mounting Bracket
No bracket
Carbon steel mounting bracket
Stainless steel bracket
 Code 9
C
E
 Nameplate
Chinese
English
 Code
M
d
i
k
p
 Option
LCD display Meter
Flameproof Ex d IIC T4~T6
Intrinsic safety Ex ia II C T4~T6
Oil Prohibition
Stainless steel tag label
 eg: Smart Absolute Pressure Transmitter
[B] Accuracy: 0.1%
[H] Output: (4~20)mA & HART
[5] Measuring range:(0-1.86~186)kPa
[N] Process Connection: NPT1/4 Male
[3] Isolating diaphragm: Hastelloy
[N] O-ring material process flange: NBR
 ASP2003BH-5N3N0E-Mip
[0] Mounting Bracket: No bracket
[E] Nameplate: English
[M] Optional: LCD display Meter
[i] Optional: Intrinsic safety Ex ia II C T4~T6
[P] Option: Stainless steel tag label

FAQ:
1. Q: Are you manufacturer or trading company?
A: We are A professional manufacturer of Pressure/Temperature sensor, wireless transmitters, gateways, even the total solutions of IIOT for more than 11 years in China. With 4~20mA, Hart, Rs485 & Modbus protocols, pressure sensors with 4~20mA, 0.5~4.5V, UARTand etc, also wireless IOT measurement transmitters. We provide high quality products with high competitive factory price.
 
2. Q: Whats your quality control system?
A: As an ISO9001:2008 certificated manufacturer, we have strict quality control system, and each product is done fatigue testing, calibration, temperature compensation before shipment. High quality is guaranteed.
 
3. Q: Is there MOQ with your product?
A: We have no MOQ limits, 1pc for testing is acceptable.
 
4. Q: Do you provide customized products?
A: Yes, we can print your logo on our products; OEM, ODM & customization are welcomed.
 
5. Q: What is the warranty of your products? And after-sales service?
A: Our warranty time is 12 months after shipment, and our after-sales will respond with your questions in 24hrs, remote instruction by PC network is always available.
 
6. Q: What is lead time of your product?
A: We are factory, our lead time is always within 10~15 working days for products without customization, but lead time will vary based on different products. You can check detail lead time with our sales.

7. Q: What international certificates do you have for your products?
A: we have gained CE, RoHs certificates, and are in the process of gaining ATEX & UL certificates now.